Structural inspection for buildings in use
TECO MSC inspects the structural condition of schools, factories, offices and buildings in use, and reviews renovation designs before work starts. TECO engineers survey the site, scan reinforcement, test concrete and re-check load-bearing capacity. The result is a report on the existing condition, the extent of damage and the recommended fix, so the owner can decide whether to repair, strengthen, renovate or leave as is.
Buildings we serve: schools, factories, offices, commercial buildings and houses in Ho Chi Minh City and southern Vietnam.
When a structural inspection is needed
- Before renovation, adding floors or a change of use: can the existing slabs, beams and columns carry the new loads, and what needs strengthening.
- Ageing buildings showing deterioration: cracked walls, beams or slabs, settlement, spalling concrete, corroded reinforcement.
- Factories: steel frames, floors and slabs when machine loads increase, cranes are added or production lines change.
- Before installing rooftop solar: checking the roof structure and purlins against the added load.
- After an incident (cracking, settlement, fire, flooding, long-term leaks): cause, extent of damage and remedial solution.
What the inspection covers
- Condition survey: recording cracks, deformation, leaks and corrosion; measuring members again when drawings are missing.
- Rebar scanning: position, quantity and concrete cover of reinforcement in columns, beams and slabs.
- Concrete testing: strength and quality with non-destructive equipment; core drilling where needed.
- Document check: comparing design and as-built drawings (if available) with the actual building.
- Calculation: re-checking load-bearing capacity under current loads and loads after renovation.
Renovation design review
When the owner already has a renovation design, TECO reviews it before construction:
- Architecture, structure and MEP review.
- Demolition, strengthening and connection details to the existing structure.
- Consistency between the design and the actual building.
- Construction methods while the building stays in use: noise, dust and safety of occupants.
How we work
- Brief: purpose of the inspection, available design and as-built drawings.
- On-site survey and testing: scheduled by zone and time so the building keeps operating.
- Load-bearing calculation.
- Report: existing condition, test results, load-bearing assessment and recommended fix.
- Renovation design review (on request) and repair or strengthening works if the owner appoints TECO.
Capability
- TECO holds a Grade II construction capability certificate (design, design review, construction) no. HCM-00062710.
- TECO structural engineers carry out the survey and calculations, using dedicated rebar scanners and concrete testing equipment.
- One contact from inspection and design review through to repair and renovation works.
Completed projects
- Structural safety assessment and 6th-floor renovation design review – Sao Viet School – rebar scanning and concrete testing of columns, beams and slabs while the school stayed open.
Frequently asked questions
Can you inspect a building without its original drawings?
Yes. TECO surveys and measures the existing building and scans reinforcement as the basis for calculation.
Does the building have to close during the inspection?
Usually not. The survey is split by zone, and drilling is done outside working hours.
What is the difference between inspection and design review?
An inspection assesses the existing building. A design review checks the renovation design before construction. Renovation projects usually need both.
Can TECO carry out the repairs after the inspection?
Yes, if the owner requests – see Upgrading and renovation.
Request a survey and quotation
TECO MSC provides structural inspection and design review in Ho Chi Minh City and southern Vietnam. Hotline: +84 911 111 929 · Send a survey request
Related services: Upgrading and renovation · Waterproofing and leak repair · Metal roof leak repair · Routine maintenance